Thermasol pro 395 manual


















All products must be installed in accordance with installation instructions provided. Read warnings on page 2. For illustrative purposes only.

Consult with qualified professional for steam room construction details. If you are installing the unit or thinking of adding one on your next project, you will need to make sure the unit is sized properly. The set of numbers in the generator model number represents the maximum capacity.

Example: Generator model PRO will be sufficient up to cubic feet with a ceiling not exceeding. Up-size 1 Unit size for every foot over 8 foot to a maximum of 10 foot. We do not recommend a ceiling height exceeding 10 feet. Lowering ceiling height to 8 feet helps create a more efficient steam room. The size of the shower will determine the size of the generator. The size of the generator will determine electrical requirements.

Type THHN. Typical locations include: closet, vanity cabinet, climate controlled attic or basement. Be sure to install unit in a location that offers easy accessibility for servicing of generator. Power Flush maintenance is recommended every minutes of use. DO NOT install generator or plumbing lines in unheated attic or any locations where water could freeze. Generator may be installed up to 50 feet away from steam shower and must be in a dry, non-combustible, well ventilated space with 6" clearance around generator.

The control cable provided with the generator is 50 feet in length Item When locating the control unit, place it as far as possible away from the steam head and as close as is practical to where the user will be sitting.

The generator must be upright, accessible and on a level surface with all connections on top. Access panel must be unobstructed and allow for easy access. DO NOT plumb the pressure relief valve into the steam line. Plumbing the pressure relief valve into the steam line can be hazardous, should the steam outlet be capped off or obstructed. Recommend installing unions on all rigid pipe lines for ease of removal and serviceability if required.

B The drain pan is required for installation. D Connect a tee to the existing cold water line. E Install a brass shut off valve on the water inlet line in an accessible area in front of the brass union and.

A stainless steel water supply flex connector may be used. F Pre-Installed water line debris screen included in the water inlet on the generator. Before making the water connection, flush the water line into a five-gallon pail to remove any silt or other materials that may be in the water inlet line.

All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Now offered in three distinct models, the Pro Series combines the latest technology with ThermaSol durability, performance and efficiency to ensure a consistent steam shower experience every time. Each Pro Series model is crafted with the same industrial grade stainless steel and lifetime warranty, plus performance-engineered to deliver constant steam at a constant rate, split-tank technology and state-of-the-art energy efficiency technology.

Pro Series III offers the next level of sophistication with an advanced cleaning system and a stainless steel drain pan. Pro Series III is the only model to feature the ultimate in smart steam temperature control.

PRO Series III As one of the industry's most technologically advanced and robust steam generators today, the Pro Series has reset expectations for achieving modern wellness at home.



0コメント

  • 1000 / 1000